Plus quam XX annos experientiae in fabricatione

LQ Typus Arcae (Moduli) Fabricatores Refrigerationis Aeris

Descriptio Brevis:

Refrigeratio aeris typus arcae (moduli) oeconomica et constantis: compressor refrigerationis compressorem typum omnino inclusum importatum notae clarae adoptat. Sonitus parvi et efficaciae magnae est.
Refrigeratorium aereum typi arcae (moduli) facile operandum: operatio quotidiana refrigeratorii in tabula moderatrice incumbit, et facile operatur, eum per PLC SEIMENS importatum constituere potes.

Conditiones Solutionis
Depositum 30% per T/T cum mandatum confirmatur, reliquum 70% per T/T ante navigationem. Vel litterae creditae irrevocabiles in conspectu.

Garantia: duodecim menses post diem B/L.

Instrumentum ideale industriae plasticae est. Adaptatio facilior et commodior, labores et sumptus conservat, ut clientes nostros efficacius adiuvet.


Detalia Producti

Etiquettae Productarum

Descriptio Producti

● Oeconomia et constans: compressor refrigerationis compressorem omnino inclusum, importatum et notam claram, adhibet; est parvus sonitus et magnae efficientiae.
● Facilis usus: operatio quotidiana refrigeratoris in tabula moderatrice incumbit, et facile operatur, eam per PLC SEIMENS importatum configurare potes.
● Summa efficax et flexibilis: refrigerator aëris turrim refrigeratoriam et antliam configurare non debet, aquam congelatam praebere pergere potest.
● Cursus tutus: refrigerator has functiones habet: commutator aeris, praesidium contra nimium thermalem, praesidium contra pressionem altam et humilem, praesidium potentiae, et receptaculum aquae.
● Unitates modulares praeter supra dictas proprietates, sed etiam sequentes commoditates habent.
● Multae unitates separatim operari et regere possunt, singuli compressores secundum condicionem operationis, ordine incipientes vel sistentes, parvo effectu in reticulum electricum, stabilitate operationis, efficacia parvis fluctuationibus. ● Multae series systematum refrigerationis independentium, si defectus in unitatibus fiat, operationem normalem aliarum unitatum non afficient, ita garantia salutis alta est. Compressor libere accendere vel extingui potest secundum mutationes quantitatis frigoris, vim aliarum unitatum intercludens, ut finis conservationis energiae consequatur.

Specificatio

Specificatio et typus capsae parametri (moduli) refrigeratoris aeris
Modellum STSF -3 -5 -8 -10 -12 -15 -20 -25 -30 -40 -50 -60 -80 -100 -120 -150 -200
Potentia compressoris kw 2.68 4.43 7.00 9.06 9.24 11.25 13.90 17.49 20.40 27.80 34.98 40.80 55.60 69.96 83.40 104.94 139.92
HP 3 5 8 10 12 15 20 25 30 20x2 25x2 15x4 20x4 25x4 20x6 25x6 25x8
Capacitates refrigerandi KcaVh 9000 1260D 20800 28300 31600 45494 62264 78604 90988 12452 15720 18197 24905 31941 37358 47162 62883
kw 11.05 16.9S XXIV.XX 32.91 36.74 52.90 72.40 91.40 105.80 144.80 182.80 211.60 289.60 365.60 434.40 548.40 731.20
Cryogenum Oxyleon R22
tensio alimentationis 3/N/PE AC380V Functio tutelae addenda
Functio tutelae Protectio refrigerationis contra pressionem altam et humilem, protectio contra vitia systematis aquarii, protectio contra congelationem, protectio contra calorem et onus compressoris.
Vis ad antliam aquae refrigerandae 0.55 (chiliogrammata) 0.75 1.10 (chiliogrammata) 1.50 (chiliogrammata) 2.20 (chiliogrammata) 3.00 (chiliogrammata) 3.00 (chiliogrammata) 3.00 (chiliogrammata) 3.00 (chiliogrammata) 4.00 (chiliogrammata) 4.00 (chiliogrammata) 7.50 (chiliogrammata) 7.50 (chiliogrammata) 7.50 (chiliogrammata) 7.50 (chiliogrammata) 7.50 (chiliogrammata) 11.00 (chiliogrammata)
Fluxus aquae refrigeratae 3 (T/h) 4 (T/h) 6 (T/h) 8 (T/h) 10 (T/h) 12 (T/h) 15 (T/h) 20 (T/h) XXV (T/h) 30 (T/h) 40 (T/h) 50 (T/h) 60 (T/h) 80 (T/h) 80 (T/h) 85 (T/h) 120 (T/h)
Diameter tubi aquae refrigeratae 1 (DN) 1 (DN) 1.5 (DN) 1.5 (DN) 2 (DN) 2 (DN) 2 (DN) 2.5 (DN) 2.5 (DN) 2.5 (DN) 2.5 (DN) 80 (DN) 80 (DN) 100 (DN) 125 (DN) 125 (DN) CL (DN)
Potentia ventilabri 0.30 (chiliogrammata) 0.38 (chiliogrammata) 0.55 (chiliogrammata) 0.96 (chiliogrammata) 0.96 (chiliogrammata) 1.10 (chiliogrammata) 1.35 (chiliogrammata) 1.35 (chiliogrammata) 1.65 (chiliogrammata) 1.65 (chiliogrammata) 2.20 (chiliogrammata) 4.70 (chiliogrammata) 4.70 (chiliogrammata) 6.00 (chiliogrammata) 6.00 (chiliogrammata) 6.00 (chiliogrammata) 8.00 (chiliogrammata)
Dimensio
1200 (L) 1250 (L) 1400 (L) 1500 (L) MDCC (L) 1660 (L) 2050 (L) 2500 (L) 2650 (L) 2500 (L) 3200 (L) 3200 (L) 3500 (L) 3850 (L) 4500 (L) 5000 (L) 5500 (L)
DC (Occidens) DCCL (Occidens) 900 (O) 950 (O) 950 (O) 950 (O) 1200 (O) 1200 (O) 1200 (O) 1660 (Occidens) 1660 (Occidens) 1650 (Occidens) MDCCC (Occidens) MM (O) MM (O) MM (O) 2600 (O)
1350 (H) 1350 (H) 1400 (H) 1500 (H) 1500 (H) 1500 (H) MDCCXXX (H) MDCCXXX (H) MDCCCL (H) 2170 (H) 2010 (H) MMCC (H) MMCC (H) 2400 (H) 2400 (H) 2400 (H) 2600 (H)
Pondus 160 (chilogrammata) 200 (chilogrammata) 320 (chiliogrammata) 450 (chilogrammata) 600 (chilogrammata) 750 (chilogrammata) 900 (chilogrammata) 1100 (chilogrammata) 1300 (chilogrammata) 1500 (chilogrammata) 1800 (chilogrammata) 2200 (chiliogrammata) 2500 (chiliogrammata) 2800 (chilogrammata) 2800 (chilogrammata) 3200 (chiliogrammata) 3200 (chiliogrammata)
Conditio refrigerationis: temperatura evaporationis: 7.5℃; temperatura condensationis: 355℃

● Specificatio et parametri moduli conversionis integrati refrigerationis aeris chilleris.
● Temperatura evaporationis: 2℃; Temperatura condensationis: 35℃.
● Parametri variantur cum mutatione temperaturae evaporationis et temperaturae condensationis.

Modellum STSF 18 22.5 30 37.5 48 52.5 62.5 80 112.5 157.5 ducenti 272 trecenti
Potentia pro Compressore kW frequentiae humilis 4,84 6.2 8.48 10.54 13.76 14.06 16.73 13.76 10.54 14.06 13.76 13.76 14.06
Alta frequentia kW 10.57 14.38 18.74 23.8 30.5 33.9 41.8 50.05 68.08 98 128.1 CLXV 180.8
Capacitas Refrigerandi kW frequentiae humilis 28.8 38.7 48.7 62.5 82.8 89.9 103.1 82.8 62.5 89.9 82.8 82.8 89.9
Alta frequentia kW 62 83.5 107.6 135.6 173.5 185.9 196.5 294.1 413.2 575.9 776.5 993.62 1095.9
Refrigerans R410a
Tensio electrica 3P 380V 50HZ/N/PE
Functio Protectionis Protectio pressionis altae et humilis refrigerationis, protectio contra vitia systematis aquarii, protectio contra congelationem, protectio contra nimium calefactum compressoris, etc.
Potentia ad Antliam Aquae Refrigerandae 3 3 4 4.0 5.5 7.5 7.5 5.5 7.5 11 15 15 22
Fluxus Aquae Refrigeratae 12 (m³/h) 15 (m³/h) 25 (m³/h) 30 (m³/h) 30 (m³/h) 32 (m³/h) 35 (m³/h) 45 (m³/h) 60 (m³/h) 85 (m³/h) 120 (m³/h) 150 (m³/h) 165 (m³/h)
Tubus Aquae Refrigeratae 40 (DN) 50 (DN) 65 (DN) 65 (DN) 65 (DN) 65 (DN) 65 (DN) 80 (DN) 100 (DN) 100 (DN) 125 (DN) CL (DN) CL (DN)
Numerus fanorum
2 (m³/h) 3 (m³/h) 4 (m³/h) 4 (m³/h) 6 (m³/h) 6 (m³/h) 8 (m³/h) 6 (m³/h) 12 (m³/h) 12 (m³/h) 18 (m³/h) 24 (m³/h) 30 (m³/h)
Potentia ventilabri
1.4 (DN) 1.65 (DN) 2.2 (DN) 2.2 (DN) 3.12 (DN) 3.3 (DN) 4.4 (DN) 8.22 (DN) 9.36 (DN) 16.44 (DN) 24.66 (DN) 31.68 (DN) 39.6 (DN)
Dimensio
2060 (L) 2550 (L) 2650 (L) 2800 (L) 2700 (L) 3000 (L) 3600 (L) 4000 (L) 4200 (L) 4800 (L) 6900 (L) 9000 (L) 9000 (L)
1206 (Occidens) 1250 (Occidens) 1450 (O) 1500 (O) 1660 (Occidens) 1700 (O) 1700 (O) 2200 (O) 2200 (O) 2400 (O) 2400 (O) 2400 (O) 2400 (O)
MDCC (H) MDCCXX (H) MM (H) MMCC (H) 2210 (H) 2340 (H) 2340 (H) 2350 (H) 2350 (H) 2400 (H) 2400 (H) 2400 (H) 2400 (H)
Pondus
750 (chilogrammata) 950 (chilogrammata) 1000 (chilogrammata) 1100 (chilogrammata) 1500 (chilogrammata) 1800 (chilogrammata) 2200 (chiliogrammata) 2500 (chiliogrammata) 2800 (chilogrammata) 3200 (chiliogrammata) 3500 (chilogrammata) 4800 (chilogrammata) 5200 (chiliogrammata)

  • Praecedens:
  • Deinde: